The RAID Controller produces diagnostic error messages at reboot.
  • Many of these Power-On Self-Test (POST) messages are self explanatory and suggest corrective actions for troubleshooting.
  • Details of these messages and corrective actions are provided in the following table.
  • Not all the messages in the table will apply to every system or controller.
CodeMeaningRecommended Action
1702SCSI cable error detected. System halted.This message indicates a termination or cabling problem with the system board integrated SCSI controller. Check Cabling and termination
1720Slot x Drive Array – S.M.A.R.T. Hard Drive Detects Imminent Failure: SCSI Port x: SCSI ID xThe indicated drive has reported a S.M.A.R.T. predictive failure condition, and may fail soon. Do not replace the drive unless all other drives on the array are on-line! Back up data before replacing drive(s).
1721Slot x Drive Array – Drive Parameter Tracking Predicts Imminent Failure. The following device(s) should be replaced when conditions permit:Do not replace drive unless all other drives on the array are on-line! Back up data before replacing drive(s). M&P predictive failure threshold exceeded condition. The indicated drive may fail at some time in the near future.
1723Slot x Drive Array – to improve signal integrity, internal SCSI connector should be removed if external drives are attached to the same SCSI port (followed by further details).Follow the remaining instructions in the POST message.
1724Slot x Drive Array – Physical Drive Position Change(s) Detected – Logical drive configuration has automatically been updated. (RESUME = F1 KEY)This message indicates that logical drive configuration has been updated automatically following physical drive position changes. Select F1 key to resume.
1725Slot x Drive Array – Optimal SIMM (Memory Module) problem detected (followed by one of the following): 
  • SIMM has automatically been disabled due to memory errors
  • Unsupported SIMM type installed. Use 4MB Fast-Page 60-70ns Tin-Lead.
Remove or replace the problem SIMM. This message is specific to SMART-2SL controllers.
1726Slot x Drive Array - Array Accelerator Memory Size Change Detected – Array Accelerator configuration has automatically been updated (RESUME = F1 KEY)This message appears if the controller is replaced with a model that has a different amount of cache memory.
1727Slot x Drive Array - New Logical Drive(s) Attachment Detected (if >32 logical drives, this will be followed by Auto-configuration failed: Too many logical drives) (RESUME = F1 KEY)This message indicates the controller has detected an additional array of drives that was attached when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32 – additional drives will not be added to the configuration if this number is exceeded. Press the F1 key to resume.
1728Slot x drive array – abnormal shutdown detected with write cache enabled. No Array Accelerator battery backup on this model array controller. Any data that may have been in Array Accelerator memory has been lost.This POST message should never occur unless the write cache is somehow enabled on a controller that does not have batteries.
1729 Slot 1 Drive Array - disk performance optimization scan in progress – RAID 4/5 performance may be higher after completion.This message is normal following the initial configuration of RAID 4 or RAID 5 logical drives. This POST message will go away and performance of the controller will improve after the parity data has been initialized by ARM (an automatic process that runs in the background on the controller).
1753Slot x drive array – array controller maximum operating temperature exceeded during previous power up.This message appears at the next power-up if the controller locks due to excessive temperature. Check for proper operation of the server cooling fan.
1756Slot x redundant controllers are not the same model.The redundant controllers are not of the same model. Use two like model controllers for redundancy.
1757Slot x Array Accelerator daughterboard incompatible. Please replace 4MB array accelerator card with a 16MB or 64MB card.The controller does not support the attached Array Accelerator card. Attach the correct Array Accelerator daughterboard.
1758Slot x drive array – Array Accelerator size mismatch between controllers. 64MB array accelerator should be attached to both controllers.The size of Array Accelerator cards is different between two controllers in a redundant controller configuration. Use Array Accelerator cards of the same size on both controllers.
1759Slot x drive array – redundant controller errorReplace controller or server motherboard.
1762Redundant controller operation is not supported in this firmware version. Please remove redundant controller or upgrade controller firmware. (Controller is disabled until this problem is resolved.)Remove the redundant controller or visit the Compaq website and get the latest upgrade for the controller firmware.
1763Array accelerator daughtercard is detached; please reattach. (Controller is disabled until this problem is resolved.)This controller model cannot operate if the Array Accelerator card is detached. Reattach the card.
1764Slot x drive array – capacity expansion process is temporarily disabled (followed by a cause).The capacity expansion process has been 
temporarily disabled for the reason indicated, and will automatically resume. If the array accelerator has been removed, reinstall it for capacity expansion to continue.
1765Slot x drive array Option ROM appears to conflict with an ISA card – ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with SMART-2/E 8-bit Option ROM due to EISA buffer limitations. Please remove or reconfigure the ISA card.Remove or reconfigure the conflicting ISA card, referring to the directions provided with the ISA card. Alternatively, the Option ROM can be disabled on the SMART-2/E controller via the System Configuration Utility if a SMART-2/E is not the primary (boot) controller.
1766Slot x drive array requires System ROM upgrade. Run System ROMPaq Utility.Run the latest version of System ROMPaq. See Chapter 4 for details.
1767Slot x drive array option ROM is not programmed correctly or may conflict with the memory address range of an ISA card. Check the memory address configuration of installed ISA card(s) or Run Option ROMPaq Utility to attempt SMART-2/E Option ROM reprogramming.Check the memory address range of any ISA cards that may be installed, and verify that they do not conflict with the address of the SMART-2/E Option ROM as shown via the System Configuration Utility. If there is no conflict, run Option ROMPaq and attempt to reprogram the SMART-2/E Option ROM 
1768Slot x drive array – resuming logical drive expansion process.No action required. This message appears whenever a controller reset or power cycle occurs while array expansion is in progress.
1769Slot x drive array – drive(s) disabled due to failure during expansion (possibly followed by additional details).Data has been lost while expanding the array; therefore, the drives have been temporarily disabled. Press F2 to acknowledge the data loss and re-enable the logical drives. Restore data from backup. If the Array Accelerator has failed, replace the Array Accelerator board after the capacity expansion process has terminated. 
NEVER turn off the system and replace the Array Accelerator board if capacity expansion is in progress.
1770Slot x Drive Array – Critical Drive Firmware Problem Detected – Please upgrade firmware on the following drive(s) using Options ROMPaq (available from [url]www.compaq.com[/url]): SCSI Port (y) SCSI ID (x)  (RESUME = F1 OR F2 KEY)The indicated drives are running firmware that may cause intermittent problems. Please use the Compaq “Options ROMPaq” utility to upgrade firmware on all drives to the latest revision.
1774Slot x drive array – obsolete data found in Array Accelerator. Data found in  accelerator was older than data found in drives. Obsolete data has been discarded.Data found in Accelerator is older than data found on drives due to drives having been disconnected, used on another controller, then reconnected. Press F1 to discard older data.
1775Slot x Drive Array – ProLiant Storage System Not Responding SCSI Port (y): Check storage system power switch and cables. Turn the system power off while checking the ProLiant power and cable connections, then turn the system power back ON to retry. (RESUME = F1 KEY)Turn off power to system. Check external ProLiant power switch – external drives must all be powered up before or at the same time as the main system. Check cables. If retry does not help, try updating the ProLiant System firmware, or try replacing the cable, ProLiant storage backplane, or the array controller.
1776Slot x Drive Array – SCSI Bus Termination Error – Internal and external drives cannot both be attached to the same SCSI port. SCSI port (y): Check cables (RESUME = F1 KEY)The internal and external connectors of the specified SCSI port(s) are both attached to drives. The SCSI bus is not properly terminated when internal and external drives are attached concurrently to the same SCSI bus. The indicated SCSI bus is disabled until this problem is resolved. Turn off the server power and check the cabling to the specified SCSI port
1777Slot x Drive Array – ProLiant Drive Storage Enclosure Problem Detected (followed by one or more of the following): 
  • SCSI Port (y): Cooling Fan Malfunction Detected
  • SCSI Port (y): Overheated Condition Detected
  • SCSI Port (y): Side-Panel must be Closed to Prevent Overheating
  • SCSI Port (y): Redundant Power Supply Malfunction Detected
  • SCSI Port (y): Wide SCSI Transfer Failed
  • SCSI Port (y): Interrupt Signal Inoperative
(RESUME = F1 KEY)
Check cooling fan operation by placing hand over fan. Check internal plenum cooling fan in tower servers or storage systems. If fan is not operating, check for obstructions and check all internal connectors. Replace unit side panel if removed. If the ProLiant Storage System power LED is amber instead of green, this can indicate a fan failure, redundant power supply failure, or thermal problem. Check SCSI cables. If the message indicates to check SCSI cables, please verify the cabling against the diagrams in the User Guide. If the routing is correct, replace cables on the specified port until the POST message is eliminated.
1778Slot x Drive Array resuming Automatic Data Recovery process.No action required. This message appears whenever a controller reset or power cycle occurs while Automatic Data Recovery is in progress.
1779Slot x Drive Array - Replacement drive(s) detected OR previously failed drive(s) now appear to be operational: Port (y): SCSI ID (x): 
  • Restore data from backup if replacement drive x has been installed.
  • If this message appears and drive x (identified by its SCSI ID) has not been replaced, this indicates an intermittent drive failure. 
 This message also appears once immediately following drive replacement before data is restored from backup.
1783Slot x Drive Array Controller Failure.If this message appears immediately following a ROM installation, the ROM is defective or not installed properly. Check that the controller is firmly inserted in its slot. Check for improper cabling or SCSI ID conflicts. Try upgrading the System ROMs. Otherwise, replace the array controller.
1784Slot x Drive Array Drive Failure. The following
SCSI drive(s) should be replaced: SCSI port (y)
SCSI ID (x)
Check for loose cables. Replace defective drive x and/or cable(s).
1785Slot 1 Drive Array not Configured (may be followed by one of the following): 
  1. No drives detected
  2. Drive positions appear to have changed – Run Drive Array Advanced Diagnostics if previous positions are unknown. Then turn system power OFF and move drives to their original positions.
  3. Configuration information indicates drive positions beyond the capability of this controller. This may be due to drive movement from a controller that supports more drives than the current controller.
  4. Configuration information indicates drives were configured on a controller with a newer firmware version.
(RESUME = F1 KEY)
  1. Turn off system and check SCSI cable connections to make sure drives are attached properly.
  2. Run Drive Array Advanced Diagnostics if previous positions are unknown. Then turn system power OFF and move drives to their original positions. 
  3. To avoid data loss, turn system power OFF and reattach drives to the original controller.
  4. To avoid data loss, reattach drives to the original controller or upgrade the controller firmware to the version on the original controller using Option ROMPaq. 
Select F1 key to resume.
1786Slot 1 Drive Array Recovery Needed. The following SCSI drive(s) need Automatic Data Recovery: SCSI Port (y): SCSI ID (x) 
  • Select F1 to continue with recovery of data to drive(s). 
  • Select F2 to continue without recovery of data to drive(s). 
Or, Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously Aborted! The following SCSI drive(s) need Automatic Data Recovery (Rebuild): SCSI Port (y): SCSI ID (x) 
  • Select F1 to retry Automatic Data Recovery to drive. 
  • Select F2 to continue without starting Automatic Data Recovery data to drive.
The message normally appears when a drive was replaced in a fault-tolerant configuration when system power was OFF. In this case, press F1 to start the automatic data recovery process. The “previously aborted” version of the 1786 POST message will appear if the previous rebuild attempt was aborted for any reason. Run the Array Diagnostics Utility (ADU) for more information. If the replacement drive was failed, try using another replacement drive. If rebuild was aborted due to a read error from another physical drive in the array, back up all readable data on the array, run Diagnostics Surface Analysis, and then restore the data.
1787Slot x Drive Array Operating in Interim Recovery Mode. The following SCSI drive(s) should be replaced: SCSI Port (y): SCSI ID (x)Following a system restart, this message is a reminder that drive x is defective and fault tolerance is being used. Drive x needs replacement as soon as possible. A loose or defective cable may also cause this error.
1788Slot x Drive Array Reports Incorrect Drive Replacement. The following SCSI drive(s) should have been replaced: SCSI Port (y): SCSI ID (x). The following SCSI drive(s) were incorrectly replaced: SCSI Port (y): SCSI ID (z). 
  • Select F1 to continue - drive array will remain disabled.
  • Select F2 to reset configuration - all data will be lost.
  • Or, Faulty power cable connection to the drive.
  • Or, Defective SCSI cable.
The drives indicated were installed in the wrong place, so they have been disabled. Reinstall the drives correctly. 
Press F1 to restart the computer with the drive array disabled. 
Press F2 to use the drives as configured and lose all the data on them. 
Repair the connection and press F2. If this message is not eliminated by pressing F2, run the Drive Array Advanced Diagnostics Utility.
1789Slot x Drive Array SCSI Drive(s) Not Responding. Check cables or replace the following SCSI drives: SCSI Port (y): SCSI ID (x) 
Select F1 to continue - drive array will remain disabled. 
Select F2 to failed drives that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance.
This message indicates that previously operating drives are missing or inoperative following a cold or warm reset. Turn off system and check cable connections. If cables are connected, replace the drive. 
Press F1 to restart the computer with the drive array disabled. 
Press F2 If not wanting to replace the drives now.
1792Slot x valid data found in Array Accelerator. Data automatically written to drive array.Power was interrupted while the system was in use, or the system was restarted while data was in the Array Accelerator memory. Power was restored within four days.
1793Slot x drive array – Array Accelerator battery depleted. Data in Array Accelerator has been lost. (Error message 1794 also displays.)While the system was in use, power was interrupted while data was in the Array Accelerator memory. Power was not restored within four days, so the batteries were depleted and data in the Array Accelerator was lost. Check all files for potential data corruption. 
Or, The Array Accelerator batteries have failed.
1794Slot x drive array – Array Accelerator battery charge low. Array Accelerator is temporarily disabled. Array Accelerator will be re-enabled when battery reaches full charge.The battery charge is below 90%. Posted writes are disabled. When the batteries are fully charged, the Array Accelerator will automatically be re-enabled and this POST message will no longer display. Replace the Array Accelerator or the Smart Array Controller if batteries do not recharge within 36 power-on hours.
1795Slot x drive array – SMART-2 Controller configuration error. Data does not correspond to this drive array. Array Accelerator is temporarily disabled.The data stored in the Array Accelerator does not correspond to this drive array. Match the Array Accelerator to the correct drive array. 
Or, Run the Compaq System Configuration Utility to clear data in the Array Accelerator.
1796Slot x drive array – Array Accelerator is not responding. Array Accelerator is temporarily disabled.Replace the Array Accelerator or the Smart Array Controller.
1797Slot x drive array – Array Accelerator read error occurred. Data in Array Accelerator has been lost. Array Accelerator is disabled.Replace the Array Accelerator or the Smart Array Controller. Restore data from backup.
1798Slot x drive array – Array Accelerator write error occurred. Array Accelerator is disabled.Replace the Array Accelerator or the Smart Array Controller. Restore data from backup.
1799Slot x drive array – drive(s) disabled due to Array Accelerator data loss. 
Select F1 to continue with logical drives disabled. 
Select F2 to accept data loss and re-enable logical drives.

Data stored in the Array Accelerator has been lost; therefore, the drives have been temporarily disabled. 
Press F2 to acknowledge the data loss and re-enable the logical drives. Restore data from backup.

转载于:https://blog.51cto.com/lucky2012/141804

本文内容由网友自发贡献,版权归原作者所有,本站不承担相应法律责任。如您发现有涉嫌抄袭侵权的内容,请联系:hwhale#tublm.com(使用前将#替换为@)

HP 阵列卡错误代码 的相关文章

随机推荐

  • 如何理解Apache License, Version 2.0(整理)

    如何理解Apache License Version 2 0 xff08 整理 xff09 问题 xff1a 最近看到apache发布了2 0版本的License 而且微软也以此发布了部分源代码 我对OpenSource不是特熟 xff0c
  • 网页视频流m3u8/ts视频下载

    现在很多视频网站播放流视频 xff0c 都不是采用mp4 xff0f flv文件直接播放 xff0c 而是采用m3u8 ts这种方式播放 简单说就是 xff0c 网站后台把视频切片成成百上千个xx ts文件 xff0c 一般10秒一个 xf
  • Windchill的JSP页面跳转到Ext页面的分析

    今天花了一天时间 xff0c 看了一块代码 xff0c 低效但是不得不看懂 具体内容是这样的 xff1a Windchill中按钮菜单栏嵌入了一个菜单项 xff0c 点击它会触发弹出一个新的浏览器页面 xff0c 相当于弹框 xff0c 让
  • C++类的定义和声明怎么写

    C 43 43 语言可以看成是C语言的扩展和改进 xff0c 相对于C语言 xff0c C 43 43 语言主要是增添了面向对象的特性 类 xff08 Class xff09 则是C 43 43 面向对象编程的实现方式 无论是何种编程语言
  • jmeter-常用性能指标分析

    概述 我们在用jmeter做性能测试的时候 xff0c 有一些关键性的性能指标需要去分析 但是由于开源工具本身的局限性 xff0c 这些指标在工具中的命名极易对我们造成混淆 所以我们需要对这些指标一一进行剖析 指标分析 响应时间 xff1a
  • 讨论76 怎么查一下我机器的内存?AIX环境

    oracle大型数据库系统在AIX unix上的实战详解 讨论76 怎么查一下我机器的内存 xff1f AIX环境 一个读者来信问勒令一个简单问题 xff1a 怎么查一下我机器的内存 xff1f AIX环境 问题 xff0c 我这里借用or
  • 数组

    数据类型 数组名 61 new 数据类型 元素个数或数组长度 数组中最小的索引是 0 xff0c 最大的索引是 数组的长度 1 获得数组的长度 xff0c 提供了一个 length属性 xff0c 在程序中可以通过 数组名 length 的
  • 静态方法不需要有对象,可以使用类名调用

    Public static void printData 表明此类方法为类方法 xff08 静态方法 xff09 静态方法不需要有对象 xff0c 可以使用类名调用 静态方法中不允许访问类的非静态成员 xff0c 包括成员的变量和方法 xf
  • matlab练习程序(曲面拟合)

    这里用到的还是最小二乘方法 xff0c 和上一次这篇文章原理差不多 就是首先构造最小二乘函数 xff0c 然后对每一个系数计算偏导 xff0c 构造矩阵乘法形式 xff0c 最后解方程组 比如有一个二次曲面 xff1a z 61 ax 2
  • 高铁在高速运行时的电力是如何提供的?

    高铁在高速运行时的电力是如何提供的 xff1f 铁路机车是个庞大的家族 xff0c 高铁只是这个大家庭的一个新成员 xff0c 如果要连篇累牍赘述其他车辆 xff0c 恐怕这个答案是写不下的 xff0c 故本文针对高速铁路进行讨论 一 高铁
  • RS232通信协议详解

    通信协议 所谓通信协议是指通信双方的一种约定 约定包括对数据格式 同步方式 传送速度 传送步骤 检纠错方式以及控制字符定义等问题做出统一规定 xff0c 通信双方必须共同遵守 因此 xff0c 也叫做通信控制规程 xff0c 或称传输控制规
  • 学习C/C++的电子书大全

    2019独角兽企业重金招聘Python工程师标准 gt gt gt 在 学习C 43 43 的经典书籍 这篇文章中 xff0c 列出了C C 43 43 的经典书籍 xff1a C 43 43 Primer 第 5 版 中文版 英文版 Ef
  • 做Android开发的你还为找工作迷茫吗?通过直观的年薪来调准你的方向

    最近仍然有不少同学在找工作 xff0c 跳槽 现在跳槽不是一个好时机 可以看到现在的岗位明显减少了 很多公司都在赶今年的项目交付 xff0c 新的项目还没有规划好 xff0c 新一轮的融资也还没有到时间 很多在职的同学都在等到拿到年终奖再跳
  • 协议栈是什么

    1 协议栈是什么 简介 协议栈 xff0c 英语名称为Protocol stack xff0c 又称协议堆叠 xff0c 是计算机网络协议套件的一个具体的软件实现 协议套件中的一个协议通常是只为一个目的而设计的 xff0c 这样可以使得设计
  • 给linux杀杀毒吧

    linux是非常先进的 xff0c 但是没有绝对的安全 所以来杀杀毒吧 xff1a ClamAV是一个在命令行下查毒软件 xff0c 因为它不将杀毒作为主要功能 xff0c 默认只能查出您计算机内的病毒 xff0c 但是无法清除 xff0c
  • 服务器编程的语言,服务器编程语言的配置与CMS系统

    做过 1 服务器编程函数禁用找到 disable functions 61 该选项可以设置哪些服务器编程函数是禁止使用的 服务器编程中有一些函数的风险性还是相当大的 可以直接执行一些CentOS系统级脚本命令 如果允许这些函数执行 当服务器
  • Linux中断与进程切换,结合中断上下文切换和进程上下文切换分析Linux内核的一般执行过程...

    64 实验环境 OS Linux cj virtual machine 5 3 0 51 generic 虚拟机 QEMU 内核版本 5 3 4 调式方法 GDB PS xff1a 调试环境安装请看上一篇博客汇编级理解Linux系统调用 f
  • 【FreeRTOS】栈生长方向 portSTACK_GROWTH

    FreeRTOS新建任务时 xTaskCreate 函数有这样一段注释 span class token comment 代码已简化 span span class token comment If the stack grows down
  • 十大畅销【操作系统类】书籍,说说你看过哪本

    鸟哥的Linux 私房菜 深入理解计算机系统 Linux内核设计与实现 UNIX操作系统设计 操作系统是控制其他程序运行 xff0c 管理系统资源并为用户提供操作界面的系统软件的集合 操作系统 xff08 英语 xff1b Operatin
  • HP 阵列卡错误代码

    POST Error Messages The RAID Controller produces diagnostic error messages at reboot Many of these Power On Self Test PO